INCH-POUND
A-A-50473B
June 21, 1993
SUPERSEDING
A-A-50473A
April 11, 1989
COMMERCIAL ITEM DESCRIPTION
OILERS, HAND, PUSH-BOTTOM
The General Services Administration has authorized the use of this commercial item description in preference to Federal Specification GGG-O-592, type I, class A.
Abstract. This CID covers the requirements for push-bottom hand oilers. The oiler shall be of cold-rolled steel. The oiler shall consist essentially of a top section with spring-action bottom, a washer, and a threaded removable spout.
Salient characteristics.
1. Oiler description. The oiler shall be similar to figure 1. The oiler body and spout shall be connected by means of machine-cut threads in both parts. Material thickness and dimensions for the oiler shall be in accordance with table I for the size as specified in the contract or order. Oiler capacity requirements shall be measured in fluid ounces (fl 02).
TABLE I. Oiler dimensions
Size Code |
Capacity |
Diameter (A) |
Height (B) |
Material thickness |
||||
Wall (C) |
Bottom (D) |
|||||||
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
minimum |
Maximum |
|
|
fl oz |
inches |
inches |
inches |
||||
1 |
1/2 |
1-1/2 |
1-1/2 |
3 |
1 |
2-1/2 |
0.022 |
0.012 |
2 |
2 |
4 |
3 |
4 |
2 |
3 |
0.022 |
0.012 |
3 |
5 |
10 |
3 |
5 |
2 |
4 |
0.022 |
0.012 |
4 |
10 |
16 |
3-1/2 |
5-1/2 |
2 |
4 |
0.022 |
0.014 |
Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commanding Officer (Code 156), Naval Construction Battalion Center, 1621 Pleasant Valley Road. Port Hueneme, CA 93043-4300. |
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.