MIL-C-23044A(MC)
3.4.15 Cleaning All parts shall be clean and free from
lint, sand, metal chips and weld splashes.
3.4.16 Interior. The chest interior shall be free from
all sharp protrusions, corners, burrs, etc., that might damage
the fabric tank (see 6.1).
3.5 Performance and product characteristics.
3.5.1 Lid operation. Initially, and after any of the
conditions specified herein, it shall be possible to install
and to remove the chestlid by normal procedures. With the
lid lugs engaged by the hold-down devices, and the latches
disengaged, it shall be possible to raise the lid and dis-
engage it from the chest body.
3.5.1.1 End for end rotation. The lid shall be capable
in addition to the requirements of 3.5.1.
of rotating
3.5.2 Lifting. The chest, with the lid latched in place
shall be capable of meeting the test specified in 4.6.3 with-
out permanent deformation or damage to the lifting hooks, the
chest, or the lid, and without any latches becoming dis-
engaged.
3.5.2.1 Bar lift. The chest, with the lid latched in
place shall be capable of meeting the test specified in
4.6.3.1 without permanent deformation or damage to the bar,
the chest, or the lid, and without any latches becoming
disengaged.
3.6 Service conditions.
3.6.1 Drop. With the lid latched in place, the chest
shall be capable of withstanding the drop tests specified
in 4.6.4. and 4.6.4.1 without being damaged beyond use and
without any latches becoming disengaged. Repairable, super-
ficial damage is to be expected and will be permitted. After
the drop test the chest shall be capable of meeting the per-
formance and product characteristics specified in 3.5.
3.6.2 Towing. With the lid latched in place (see 3.4.4)
the chest shall be capable of meeting the requirements of
4.6.5 without being damaged beyond use. During towing, no
latches shall become disengaged. Minor repairable damage
will be permitted. After towing, the chest shall be capable
of meeting the performance and product characteristics speci
fied in 3.5.