MIL-PRF-38266D
3.17 Interface details:
a. Supply tank and overflow tank shall each have a clean out access which is a minimum of 6-
inches in diameter.
b. Filler opening shall have a minimum inside clearance diameter of 1.50 inches.
c. An MS24476-1 adapter shall be provided on the tank to allow the tank to be filled by
another tank and pump unit which is equipped with mating nozzle.
d. A visual means of displaying in one-half (1/2) pint increments, the amount of fluid
pumped from the supply tank shall be provided. The volume of lubricant within the overflow tank
shall be visually displayed in 1/2 pint increments and the display shall have an adjustable pointer
(marker). If a sight glass is used, it must be guarded to prevent breakage during operation and
storage
e.. Dry weight of the unit shall be not greater than 96 pounds
f. A handle shall be provided on the overflow tank to enable the full tank to be
conveniently carried and easily emptied.
3.18 Finish
a. All painted surfaces shall be oil and corrosion resistant under all environmental
conditions specified within.
.
b. The color shall conform to FED-STD-595, Color No. 24052
c. Finishes of internal surfaces shall be corrosion resistant and compatible with the
contractor selected materials and lubricants per 3.3.
3.19 Nameplate. The unit shall have a nameplate marked with the National Stock Number, Type
Designator, and manufacturer's name and part number.
3.20 Instructions.. The unit shall have an attached operational instruction plate.
4. VERIFICATION
4.1 Classification of inspections.
a. First article inspection (see 4.2).