MIL-PRF-52747F(AT)
TABLE I. Classification of defects.
Method of
Category
Defects
examination
Major:
101
Threaded parts not as specified (see 3.2.2).
SIE 1/
102
Visual
Cleaning, treatment, finish and protective coating not as
specified (see 3.2.3).
103
Visual
Color not as specified (see 3.2.3).
104
Visual
Assembly incomplete or incorrect (see 3.3).
105
Functional
Easy of operation not as specified (see 3.6).
106
Visual
Nonslip grasp surface not as specified (see 3.6).
107
Visual
Coupler not as specified (see 3.6.1).
108
Visual
Flow control valve and markings not as specified (see 3.6.3).
109
SIE
Dimensions not as specified (see 3.6.3 and 3.8.1).
110
Visual
Strainer assembly not as specified (see 3.6.4).
111
Visual
Nozzle inlet not as specified (see 3.6.4).
112
Visual
Ground cable assemblies not as specified (see 3.6.5).
113
Gage
Weight not as specified (see 3.8.4).
114
Visual
Lubrication not as specified (see 3.9).
115
Visual
Identification or special marking missing or illegible (see 3.10).
116
Visual
Interchangeability not as specified (see 3.11).
1/ SIE = Standard Inspection Equipment
4.4.2 Defects. Conformance to 3.2.2, 3.2.3, 3.3, 3.6, 3.6.1, 3.6.3, 3.6.4, 3.6.5, 3.8.1,
3.8.4, and 3.9 thru 3.11, shall be determined by examination for defects listed in table I.
Examination shall be visual, tactile, or by measurement with SIE.
4.4.3 Test conditions. Unless otherwise specified herein, tests may be performed without
shelter and at the climatic conditions existing at the place of test. The nozzle shall operate as
specified herein without maintenance other than the contractor's recommended normal scheduled
maintenance as established by a maintenance schedule prepared and submitted by the contractor
prior to test.