4.3 First article inspection.
XX-D-370D
4.3.1 Examination. The first article pump unit shall be examined as specified in 4.5.1. Presence of one or more defects shall be cause for rejection.
4.3.2 Tests. The first article pump unit shall be tested as specified in 4.5.2. Failure of any test shall be cause for rejection.
4.4 Quality conformance inspection.
4.4.1 Sampling. Sampling for examination and tests shall be in accordance with
MIL-STD-105.
4.4.2 Examination.
4.4.2.1 Samples. Samples selected in accordance with 4.4.1 shall be examined for the major and minor defects specified in 4.5.1. AQL shall be 2.5 percent defective for major defects and
6.5 percent defective for minor defects.
4.4.3 Tests.
4.4.3.1 Samples. Samples selected in accordance with 4.4.1 shall be tested as specified in
4.5.2.2 through 4.5.2.4. AQL shall. be 6.5 percent defective.
4.5 Inspection procedure.
4.5.1 Examination. The pump unit shall be examined as specified herein for the following defects:
Major
101. Materials not as specified.
102. Materials are not-corrosion resistant or treated to be made corrosion resistant for the applicable storage and operating environment.
103. Dissimilar metals as defined in MIL-STD-889, are not effectively insulated from each other.
104. Contractor does not have documentation available for identification of material, material finishes or treatments.
105. Cylinder base and head not as specified.
106. Suction pipe not as specified.
107. Screen not as specified.
108. Bung adapter not as specified.