4.6 Examination of preparation for delivery.
4.6.1 Quality conformance inspection of pack.
4.6.1.1 Unit of product. For the purpose of inspection, a completed pack prepared for shipment shall be considered a unit of-product.
4.6.1.2 Sampling. Sampling for examination shall be in accordance with MIL-STD-105.
4.6.1.3 Examination. Samples selected in accordance with 4.6.1.2 shall be examined for the following defects. AQL shall be 2.5 percent defective:
114. Materials, methods, and containers not as specified for level A or B. Each incorrect material, method, or container shall be considered one defect.
115. Disassembly not as specified for level A.
116. Pump not preserved and openings sealed as specified for level A.
117. Unit packaging not as specified for level A.
118. Packing not as specified for level A or B.
119. Quantities packed together exceed the limitations of the applicable box for level A
or B.
120. Marking missing, illegible, incorrect, or incomplete for level A, B, or commercial.
5. PREPARATION FOR DELIVERY
5.1 Preservation and packaging. Preservation and packaging shall be level A, or commercial as specified (see 6.2.1).
5.1.1 Level A.
5.1.1.1 Disassembly. The pump unit shall be disassembled the minimum amount to provide economy in-packaging. Specifically the suction pipe and the handcrank shall be removed.
5.1.1.2 Pump. The pump interior shall be coated with lubricating oil conforming to
MIL-L-21260, grade 30. Coating shall be accomplished by pumping the oil through the pump and then draining.. The inlet and outlet openings shall be sealed with plastic or metal plugs.
5.1.1.3 Padlock, keys, and chain. Interior surfaces of the padlock shall be coated with powdered graphite and the padlock, keys, and chain preserved together in accordance with MIL-P-116, method IC-1 or IC-3.